Radiation Measurements, ( ISI ), Volume (137), No (1), Year (2020-9) , Pages (106430-106430)

Title : ( A method for assessing subject-specific counting efficiency of whole-body monitoring systems for radioiodine measurements )

Authors: mohammad karami , Seyyed Hashem Miri Hakimabad , Elie Hoseinian-Azghadi , Najmeh Mohammadi ,

Access to full-text not allowed by authors

Citation: BibTeX | EndNote

Abstract

This study aims to numerically perform individualized calibration of a whole-body monitoring system for measuring the activity of 131I internal contamination. A set of ten computational phantoms inside the whole-body counter (WBC) unit were simulated using Monte Carlo code MCNPX 2.6 to investigate the effect of various morphometric parameters on the calibration factors. The counting efficiencies for separated source organs (ε_S) were calculated to convert the response of the detectors to the activity of 131I in the thyroid and other organs. The biokinetic model of iodine was combined with human respiratory tract model (HRTM), and distribution of iodine in body organs was calculated for three hypothetical scenarios (acute) and a typical real scenario (chronic). The organ-specific counting efficiencies (CEOrgan) and the total counting efficiencies (CETotal) were obtained as a function of time after the end of 131I radionuclide intake. The results showed that the thyroid was the major contributor to the CETotal (>90%) 2 days after the end of intake. Therefore, the individualized calibration process were performed using CEThyroid which is strongly dependent on the detectors solid angle seen by the thyroid more than other influencing factors. As a summary, a practical and sufficiently fast method was introduced to estimate the individual-related CEThyroid (within ±13%) for measurement times of >2d after the end of intake, based on estimation of detectors solid angle seen by a point in front of the neck.

Keywords

, whole-body counter, Monte Carlo method, virtual calibration, reference phantoms, radiation contamination
برای دانلود از شناسه و رمز عبور پرتال پویا استفاده کنید.

@article{paperid:1080663,
author = {Karami, Mohammad and Miri Hakimabad, Seyyed Hashem and Elie Hoseinian-Azghadi and Najmeh Mohammadi},
title = {A method for assessing subject-specific counting efficiency of whole-body monitoring systems for radioiodine measurements},
journal = {Radiation Measurements},
year = {2020},
volume = {137},
number = {1},
month = {September},
issn = {1350-4487},
pages = {106430--106430},
numpages = {0},
keywords = {whole-body counter; Monte Carlo method; virtual calibration; reference phantoms; radiation contamination},
}

[Download]

%0 Journal Article
%T A method for assessing subject-specific counting efficiency of whole-body monitoring systems for radioiodine measurements
%A Karami, Mohammad
%A Miri Hakimabad, Seyyed Hashem
%A Elie Hoseinian-Azghadi
%A Najmeh Mohammadi
%J Radiation Measurements
%@ 1350-4487
%D 2020

[Download]