Title : ( Study of the Anti-Scale Magnetic Water Treatment in the Industrial Boiler )
Authors: Mostafa Gholizadeh , M. Reza Benam ,Abstract
We have investigated the effect of magnetic field on the scale formation in the industrial boilers. It was found that passing water through a static magnetic field about 6000 G reduces the scale formation and protects the boiler from internal corrosion. It seems that the presence of the magnetic field modifies the local ionic concentrations via Lorentz force and therefore changes the morphology of the mineral crystals. This effect causes the shape of the crystals change from a dendristic form to a disk-shape form that is less likely to form a scale.
Keywords
Anti Scale ; agnetic Water Treatment ; Industrial Boilers ; Crystals ;@inproceedings{paperid:1015045,
author = {Gholizadeh, Mostafa and M. Reza Benam},
title = {Study of the Anti-Scale Magnetic Water Treatment in the Industrial Boiler},
booktitle = {4th International Conference: Electromagnetic Devices and Processes in Environment Protection ELMECO-4},
year = {2003},
location = {Lublin University, pol},
keywords = {Anti Scale ; agnetic Water Treatment ; Industrial Boilers ; Crystals ;},
}
%0 Conference Proceedings
%T Study of the Anti-Scale Magnetic Water Treatment in the Industrial Boiler
%A Gholizadeh, Mostafa
%A M. Reza Benam
%J 4th International Conference: Electromagnetic Devices and Processes in Environment Protection ELMECO-4
%D 2003