Iranian Journal of Veterinary Surgery, Volume (3), No (4), Year (2011-4) , Pages (57-65)

Title : ( Echocardiographic Measurement of Systolic Time Intervals In Healthy Great Dane Dogs )

Authors: Masoud Rajabioun , Alireza Vajhi , Majid Masoudifard , Masoud Selk Ghaffari , Hakimeh Sadeghian , Mohammad Azizzadeh ,

Access to full-text not allowed by authors

Citation: BibTeX | EndNote

Abstract

Objective- to determine the range of systolic times intervals using Pulsed-wave Doppler and m-mode echocardiography in normal, healthy Great Dane dogs. Design- Descriptive study. Animals- Five healthy Raeini goats. Procedures- This study examined 30 clinically healthy Great Dane dogs by the two-dimensional, M-mode and Pulsed-wave Doppler echocardiography. The dogs were awake and unsedated. The following parameters were measured on the both Pulsed-wave Doppler and M-mode echocardiographic images: pre - ejection period (PEP), left ventricular ejection time (LVET), ratio of PEP to LVET (PEP/LVET) and the total electrical-mechanical systole (QAVC). Acceleration time of aortic flow (AT) was also measured by Doppler mode. Results- The following values have been acquired: PEP = 0.067 ± 0.010 s; LVET = 0.188 ± 0.011 s; QAVC = 0.254 ± 0.016 s and PEP/LVET = 0.354 ± 0.054 measured by M-mode echocardiography and PEP = 0.062 ± 0.009 s; LVET = 0.193 ± 0.007 s; QAVC = 0.256 ± 0.011s; PEP/LVET = 0.323 ± 0.051 and AT = 0.080 ± 0.107 s measured by Doppler echocardiography. Conclusion and Clinical Relevance- On Doppler mode, there was a significant correlation between the body weight and PEP and PEP/LVET. M-mode echocardiography showed significant correlation between the body weight and body surface area and QAVC. Results of this study revealed the importance of determination of breed-specific echocardiographic parameters and indices, and evaluating of measured values with range using same method for accurate diagnosis.

Keywords

, echocardiography, systolic time intervals, Great Dane, M-mode, Pulsed-wave Doppler.
برای دانلود از شناسه و رمز عبور پرتال پویا استفاده کنید.

@article{paperid:1026216,
author = {Rajabioun, Masoud and Alireza Vajhi and Majid Masoudifard and Masoud Selk Ghaffari and Hakimeh Sadeghian and Azizzadeh, Mohammad},
title = {Echocardiographic Measurement of Systolic Time Intervals In Healthy Great Dane Dogs},
journal = {Iranian Journal of Veterinary Surgery},
year = {2011},
volume = {3},
number = {4},
month = {April},
issn = {2008-3033},
pages = {57--65},
numpages = {8},
keywords = {echocardiography; systolic time intervals; Great Dane; M-mode; Pulsed-wave Doppler.},
}

[Download]

%0 Journal Article
%T Echocardiographic Measurement of Systolic Time Intervals In Healthy Great Dane Dogs
%A Rajabioun, Masoud
%A Alireza Vajhi
%A Majid Masoudifard
%A Masoud Selk Ghaffari
%A Hakimeh Sadeghian
%A Azizzadeh, Mohammad
%J Iranian Journal of Veterinary Surgery
%@ 2008-3033
%D 2011

[Download]