Title : ( Analysis of Magnetic Flux Linkage Distribution in Salient- Pole Synchronous Generator with Different Kinds of Inter- Turn Winding Faults )

Authors: H. Yaghobi , Kourosh Ansari , Habib Rajabi Mashhadi ,

Access to full-text not allowed by authors

Citation: BibTeX | EndNote

Abstract

Abstract: A reliable and accurate diagnosis of inter-turn short circuit faults is a challenging issue in the area of fault diagnosis of electrical machines. The purpose of this study is to present a more efficient technique in fault detection and to provide a reliable method with low-cost sensors and simple numerical algorithms which not only detects the occurrence of the fault, but also locates its position in the winding. Hence, this paper presents a novel method for diagnosis of different kinds of inter-turn winding faults in a salient-pole synchronous generator based on changes in the magnetic flux linkage. It describes the influence of inter-turn winding faults on the magnetic flux distribution of the generator. The main feature of the proposed method is its capability to identify the faulty coils under two types of inter-turn winding faults. Also, the occurrence of two other types of faults can be detected by the proposed technique. Simple algorithm, low cost sensor and sensitivity are the other features of the proposed technique. Experimental results derived from a 4- pole, 380V, 1500 rpm, 50 Hz, 50 KVA, 3-phase salient-pole synchronous generator confirm the validity of the proposed method.

Keywords

, Synchronous Generator, Fault Diagnosis, Linkage Flux Analysis, Inter-turn Winding Fault.
برای دانلود از شناسه و رمز عبور پرتال پویا استفاده کنید.

@article{paperid:1026934,
author = {H. Yaghobi and Ansari, Kourosh and Rajabi Mashhadi, Habib},
title = {Analysis of Magnetic Flux Linkage Distribution in Salient- Pole Synchronous Generator with Different Kinds of Inter- Turn Winding Faults},
journal = {Iranian Journal of Electrical and Electronic Engineering},
year = {2011},
volume = {7},
number = {4},
month = {January},
issn = {1735-2827},
pages = {260--272},
numpages = {12},
keywords = {Synchronous Generator; Fault Diagnosis; Linkage Flux Analysis; Inter-turn Winding Fault.},
}

[Download]

%0 Journal Article
%T Analysis of Magnetic Flux Linkage Distribution in Salient- Pole Synchronous Generator with Different Kinds of Inter- Turn Winding Faults
%A H. Yaghobi
%A Ansari, Kourosh
%A Rajabi Mashhadi, Habib
%J Iranian Journal of Electrical and Electronic Engineering
%@ 1735-2827
%D 2011

[Download]