Title : ( Longitudinal response uniformity of a rectangular-shaped plastic scintillator when exposed to mono-energetic gamma-rays )
Authors: H. Yazdandoust , Nima Ghal-Eh , M. M. Firoozabadi ,Abstract
The longitudinal response uniformity of the rectangular-shaped plastic scintillators used in a thermal neutron imaging system proposed by Ghal-Eh and Green in 2016 is vital for its precise measurements in quality assurance studies of boron neutron capture therapy (BNCT). The MCNPX-PHOTRACK hybrid code has been used to model the response of rectangular plastic scintillator of partially painted surface in order to reduce as much as possible the longitudinal non-uniformity which usually exist in large and/or long scintillators. The results show that the optimum uniformity corresponds to fully-polished surface which coincides with FLUKA light transport simulations.
Keywords
, Plastic scintillator; Non, uniformity; MCNPX, PHOTRACK; FLUKA@article{paperid:1075502,
author = {H. Yazdandoust and Ghal-Eh, Nima and م.م. فیروزآبادی},
title = {Longitudinal response uniformity of a rectangular-shaped plastic scintillator when exposed to mono-energetic gamma-rays},
journal = {Nuclear Instruments and Methods in physics Research A},
year = {2019},
volume = {944},
month = {November},
issn = {0168-9002},
pages = {162574--162580},
numpages = {6},
keywords = {Plastic scintillator; Non-uniformity; MCNPX-PHOTRACK; FLUKA},
}
%0 Journal Article
%T Longitudinal response uniformity of a rectangular-shaped plastic scintillator when exposed to mono-energetic gamma-rays
%A H. Yazdandoust
%A Ghal-Eh, Nima
%A م.م. فیروزآبادی
%J Nuclear Instruments and Methods in physics Research A
%@ 0168-9002
%D 2019