Microchimica Acta, ( ISI ), Volume (187), Year (2020-3) , Pages (213-213)

Title : ( Graphene oxide/polydimethylsiloxane-coated stainless steel mesh for use in solid-phase extraction cartridges and extraction of polycyclic aromatic hydrocarbons )

Authors: Amirhassan Amiri , Mehdi Baghayeri , Fatemeh Karimabadi , Ferial Ghaemi , Behrooz Maleki ,

Access to full-text not allowed by authors

Citation: BibTeX | EndNote

Abstract

The stainless steel mesh, in the form of the disk, was coated with graphene oxide and poly(dimethylsiloxane) (GO-PDMS) by sol–gel technique. The coated stainless steel meshes are loaded in the mini-column as solid-phase extraction cartridge for the fast isolation and preconcentration of polycyclic aromatic hydrocarbons (PAHs) from real water samples. The extracted PAHs (naphthalene, acenaphthene, acenaphthylene, anthracene, benz[a]anthracene, fluorene, and pyrene) were quantified by gas chromatography-mass spectrometry. The operation parameters affecting the extraction efficiency including sample volume, desorption conditions, and ionic strength were investigated. At optimized conditions, the linearity of this method is obtained from 0.001 to 20 ng mL−1 with 0.2 to 1.0 pg mL−1 limit of detection. For 5 replicates at 3 spiking levels (0.1, 1, and 10 ng mL−1), the relative standard deviations between 4.0 and 6.3% were achieved. The absolute extraction recovery varied from 89.1 to 94.7%. The enrichment factors were in the range of 2227–2367. The method has been employed in the determination of PAHs in the real water samples including well water, tap water, river water, and wastewater. Relative recoveries are between 95.2 and 100.9%.

Keywords

, GC, MS PDMS Stainless steel mesh Sol–gel, based coating SPE Sample preparation
برای دانلود از شناسه و رمز عبور پرتال پویا استفاده کنید.

@article{paperid:1084524,
author = {Amiri, Amirhassan and Mehdi Baghayeri and Fatemeh Karimabadi and Ferial Ghaemi and Behrooz Maleki},
title = {Graphene oxide/polydimethylsiloxane-coated stainless steel mesh for use in solid-phase extraction cartridges and extraction of polycyclic aromatic hydrocarbons},
journal = {Microchimica Acta},
year = {2020},
volume = {187},
month = {March},
issn = {0026-3672},
pages = {213--213},
numpages = {0},
keywords = {GC-MS PDMS Stainless steel mesh Sol–gel-based coating SPE Sample preparation},
}

[Download]

%0 Journal Article
%T Graphene oxide/polydimethylsiloxane-coated stainless steel mesh for use in solid-phase extraction cartridges and extraction of polycyclic aromatic hydrocarbons
%A Amiri, Amirhassan
%A Mehdi Baghayeri
%A Fatemeh Karimabadi
%A Ferial Ghaemi
%A Behrooz Maleki
%J Microchimica Acta
%@ 0026-3672
%D 2020

[Download]