Computer Methods and Programs in Biomedicine, Volume (224), Year (2022-9) , Pages (107000-107009)

Title : ( Comparing the inter-seed effect for some iodine-125 brachytherapy sources through a Monte Carlo simulation approach )

Authors: Hamid RezaBaghani , AzarGheibi , Ali Asghar Mowlavi ,

Access to full-text not allowed by authors

Citation: BibTeX | EndNote

Abstract

Background and Objective One of the principal deficits of TG-43(U1) dosimetry protocol is ignoring the attenuation effect of each seed during the multiseed brachytherapy implants. To take into account this shadowing effect, a parameter known as the inter-seed effect (ISE) has been introduced. Current study aims to evaluate and compare the ISE for some I-125 brachytherapy seeds through a Monte Carlo (MC) simulation approach. Methods Five different models of I-125 seeds including 6711, ProstaSeed, STM 1251, 3500, and IAI-125A were simulated by MCNPX MC Code. Validity of simulated seed models was confirmed through comparing the corresponding dosimetric parameters such as radial dose function and anisotropy function with those reported by relevant literature. Then, the ISE for each seed at different distances was determined in three seeds implant configuration. Additionally, the relevant attenuation factors (AF) were also determined for each brachytherapy source. Results The obtained results demonstrated that minimum inter-seed attenuation belongs to the ProstaSeed. In return, the maximum inter-seed attenuation was found for 3500 brachytherapy seed. The mean attenuation factor for 6711, ProstaSeed, STM 1251, 3500, and IAI-125A seed models was equal to 0.764, 0.829, 0.785, 0.594, and 0.772, respectively. Conclusions It can be concluded that the considered I-125 brachytherapy seeds show different inter-seed effects and mean AF values for the same multiseed implant arrangement. This finding can be attributed to discrepancies in internal seed design and configuration.

Keywords

, BrachytherapyIodine, 125 brachytherapy seedsInter, seed effectDose calculationsMonte Carlo simulation
برای دانلود از شناسه و رمز عبور پرتال پویا استفاده کنید.

@article{paperid:1090571,
author = {Hamid RezaBaghani and AzarGheibi and Mowlavi, Ali Asghar},
title = {Comparing the inter-seed effect for some iodine-125 brachytherapy sources through a Monte Carlo simulation approach},
journal = {Computer Methods and Programs in Biomedicine},
year = {2022},
volume = {224},
month = {September},
issn = {0169-2607},
pages = {107000--107009},
numpages = {9},
keywords = {BrachytherapyIodine-125 brachytherapy seedsInter-seed effectDose calculationsMonte Carlo simulation},
}

[Download]

%0 Journal Article
%T Comparing the inter-seed effect for some iodine-125 brachytherapy sources through a Monte Carlo simulation approach
%A Hamid RezaBaghani
%A AzarGheibi
%A Mowlavi, Ali Asghar
%J Computer Methods and Programs in Biomedicine
%@ 0169-2607
%D 2022

[Download]