Radiation and Environmental Biophysics, Volume (61), No (3), Year (2022-8) , Pages (399-406)

Title : ( Age-specific calibration for in vivo monitoring of thyroid: is it necessary? )

Authors: roghayeh sohrabi , Seyyed Hashem Miri Hakimabad , Elie Hoseinian Azghadi , Hector Rene Vega Carrillo ,

Access to full-text not allowed by authors

Citation: BibTeX | EndNote

Abstract

Usually, an age-specific calibration of detectors used for in vivo monitoring of 131I thyroid radioactivity is not performed in practice. This study aimed to investigate the reduction in uncertainty that one can expect if an age-specific calibration is performed. For this, voxel and stylized computational phantoms of the thyroid, corresponding to children at different age groups, were used to simulate the calibration process of 131I detectors used for thyroid monitoring. SCK•CEN physical phantoms were also used for this purpose. Both analytical and Monte Carlo methods (MCNPX version 2.6.0) were used to estimate the counting efficiencies of the considered detectors. The results show that the uncertainties in the assessment of thyroid activity at a distance of 20 cm would be reduced from a range of +8% to +30%, to a range from - 6% to +15% when age-specific calibration was performed. Using a calibration based on thyroids of adults would result in an overestimation of the thyroid activity for children by up to 30% at a detector-neck distance of about 20 cm; a larger overestimation may be expected at closer distances. It is concluded that age-specific calibration of in vivo monitoring systems for the thyroid is important and has to be taken into consideration to improve the reliability of thyroid dose assessment for children.

Keywords

131I; Calibration; Children; In vivo monitoring; Thyroid.
برای دانلود از شناسه و رمز عبور پرتال پویا استفاده کنید.

@article{paperid:1091569,
author = {Sohrabi, Roghayeh and Miri Hakimabad, Seyyed Hashem and Elie Hoseinian Azghadi and Hector Rene Vega Carrillo},
title = {Age-specific calibration for in vivo monitoring of thyroid: is it necessary?},
journal = {Radiation and Environmental Biophysics},
year = {2022},
volume = {61},
number = {3},
month = {August},
issn = {0301-634X},
pages = {399--406},
numpages = {7},
keywords = {131I; Calibration; Children; In vivo monitoring; Thyroid.},
}

[Download]

%0 Journal Article
%T Age-specific calibration for in vivo monitoring of thyroid: is it necessary?
%A Sohrabi, Roghayeh
%A Miri Hakimabad, Seyyed Hashem
%A Elie Hoseinian Azghadi
%A Hector Rene Vega Carrillo
%J Radiation and Environmental Biophysics
%@ 0301-634X
%D 2022

[Download]