Analytica Chimica Acta, ( ISI ), Volume (905), Year (2016-1) , Pages (85-92)

Title : ( Development of a novel mixed hemimicelles dispersive micro solid phase extraction using 1-hexadecyl-3-methylimidazolium bromide coated magnetic graphene for the separation and preconcentration of fluoxetine in different matrices before its determination by fiber optic linear array spectrophotometry and mode-mismatched thermal lens spectroscopy )

Authors: Elaheh Kazemi , Ali Mohammad Haji Shabani , Shayesteh Dadfarnia , Amir Abbasi , Mohamad Reza Rashidian Vaziri , Abbas Behjat ,

Access to full-text not allowed by authors

Citation: BibTeX | EndNote

Abstract

This study aims at developing a novel, sensitive, fast, simple and convenient method for separation and preconcentration of trace amounts offluoxetine before its spectrophotometric determination. The method is based on combination of magnetic mixed hemimicelles solid phase extraction and dispersive micro solid phase extraction using 1-hexadecyl-3-methylimidazolium bromide coated magnetic graphene as a sorbent. The magnetic graphene was synthesized by a simple coprecipitation method and characterized by X-ray diffraction (XRD), Fourier transform infrared (FT-IR) spectroscopy and scanning electron microscopy (SEM). The retained analyte was eluted using a 100mL mixture of ethanol/acetic acid (9:1) and converted intofluoxetine-b-cyclodextrin inclusion complex. The analyte was then quantified byfiber optic linear array spectrophotometry as well as mode-mismatched thermal lens spectroscopy (TLS). The factors affecting the separation, preconcentration and determination of fluoxetine were investigated and optimized. With a 50 mL sample and under optimized conditions using the spectrophotometry technique, the method exhibited a linear dynamic range of 0.4e60.0mgL1 ,a detection limit of 0.21mgL 1 , an enrichment factor of 167, and a relative standard deviation of 2.1% and 3.8% (n¼6) at 60mgL 1 level offluoxetine for intra- and inter-day analyses, respectively.

Keywords

, Dispersive micro solid, phase extraction Mixed hemimicelles solid phase extraction Ionic liquid Magnetic graphene Mode, mismatched thermal lens spectroscopy
برای دانلود از شناسه و رمز عبور پرتال پویا استفاده کنید.

@article{paperid:1094852,
author = {Elaheh Kazemi and Ali Mohammad Haji Shabani and Shayesteh Dadfarnia and Amir Abbasi and Rashidian Vaziri, Mohamad Reza and Abbas Behjat},
title = {Development of a novel mixed hemimicelles dispersive micro solid phase extraction using 1-hexadecyl-3-methylimidazolium bromide coated magnetic graphene for the separation and preconcentration of fluoxetine in different matrices before its determination by fiber optic linear array spectrophotometry and mode-mismatched thermal lens spectroscopy},
journal = {Analytica Chimica Acta},
year = {2016},
volume = {905},
month = {January},
issn = {0003-2670},
pages = {85--92},
numpages = {7},
keywords = {Dispersive micro solid-phase extraction Mixed hemimicelles solid phase extraction Ionic liquid Magnetic graphene Mode-mismatched thermal lens spectroscopy},
}

[Download]

%0 Journal Article
%T Development of a novel mixed hemimicelles dispersive micro solid phase extraction using 1-hexadecyl-3-methylimidazolium bromide coated magnetic graphene for the separation and preconcentration of fluoxetine in different matrices before its determination by fiber optic linear array spectrophotometry and mode-mismatched thermal lens spectroscopy
%A Elaheh Kazemi
%A Ali Mohammad Haji Shabani
%A Shayesteh Dadfarnia
%A Amir Abbasi
%A Rashidian Vaziri, Mohamad Reza
%A Abbas Behjat
%J Analytica Chimica Acta
%@ 0003-2670
%D 2016

[Download]